[ PCB설계 ]/2.통신, 규격, DesignGuide

RS-232(UART), RS-422, RS-432, RS-485 비교

HUMINS 2022. 5. 28. 09:10

 

SPECIFICATIONS RS-232 RS-423 RS-422 RS-485
Mode of Operation SINGLE
-ENDED
SINGLE
-ENDED
DIFFER- ENTIAL DIFFER- ENTIAL
Total Number of Drivers and Receivers on One Line 1 DRIVER
1 RECVR
1 DRIVER
10 RECVR
1 DRIVER
10 RECVR
1 DRIVER
32 RECVR
Maximum Cable Length 50 FT. 4000 FT. 4000 FT. 4000 FT.
Maximum Data Rate 460kb/s 100kb/s 10Mb/s 30Mb/s
Maximum Driver Output Voltage +/-25V +/-6V -0.25V to +6V -7V to +12V
Driver Output Signal Level (Loaded Min.) Loaded +/-5V to +/-15V +/-3.6V +/-2.0V +/-1.5V
Driver Output Signal Level (Unloaded Max) Unloaded +/-25V +/-6V +/-6V +/-6V
Driver Load Impedance (Ohms) 3k to 7k >=450 100 54
Max. Driver Current in High Z State Power On N/A N/A N/A +/-100uA
Max. Driver Current in High Z State Power Off +/-6mA @ +/-2v +/-100uA +/-100uA +/-100uA
Slew Rate (Max.) 30V/uS Adjustable N/A N/A
Receiver Input Voltage Range +/-15V +/-12V -10V to +10V -7V to +12V
Receiver Input Sensitivity +/-3V +/-200mV +/-200mV +/-200mV
Receiver Input Resistance (Ohms) 3k to 7k 4k min. 4k min. >=12k

 

Universal Asynchronous Receiver Transmitter (UART) 
UART Platform Specific Important Information

The platform integrates three Universal Asynchronous Receiver Transmitter (UART) 
controllers. Each supports up to 3.8 Mbit/s. The controllers can be used in the low-
speed, full-speed, and high-speed modes. The controllers are based on the 16550 
industry standard and communicates with serial data ports that conform to the RS-232 
interface protocol.

 

Trace spacing between DATA and DATA  50 ohm trace width & 1:1 spacing